Implant Abutment
Mostrando 1-12 de 86 artigos, teses e dissertações.
-
1. Internal and Marginal Fit and Fracture Strength of Narrow Diameter Dental Implant-Abutment Assembly
Resumo O objetivo deste estudo foi avaliar a adaptação marginal e interna de cópings metálicos em pilares sobre implantes, e a resistência a fratura de diferentes conjuntos de implantes/pilares de diâmetro reduzido, submetidos à ciclagem termomecânica ou não. Sessenta e quatro implantes/pilares (n=16) foram divididos em 04 grupos de acordo com o tip
Braz. Dent. J.. Publicado em: 2020-04
-
2. Systematic review and meta-analysis of welding procedures in one-piece cast implant-supported frameworks
Abstract The objective of this systematic review and meta-analysis was to evaluate the effect of welding techniques on implant-supported prostheses and determine whether they contribute to a better adaptation compared with a one-piece cast. A search was conducted using the PubMed/MEDLINE, Embase, and Cochrane Library databases, and articles published until N
Braz. oral res.. Publicado em: 25/11/2019
-
3. Implant-based factor as possible risk for peri-implantitis
Abstract Peri-implantitis is currently a topic of major interest in implantology. Considered one of the main reasons of late implant failure, there is an emerged concern whether implant characteristics could trigger inflammatory lesion and loss of supporting bone. The purpose of this narrative review is to provide an evidence based overview on the influence
Braz. oral res.. Publicado em: 30/09/2019
-
4. Does the implant-abutment interface interfere on marginal bone loss? A systematic review and meta-analysis
Abstract The objective of this systematic review was to compare the conical internal connection (IC) with the external hexagonal connection (EH) on the occurrence of marginal bone loss (ΔMBL). Different databases were used to carry out the selection of the elected studies. The studies were judged according to the risk of bias as “high”, “low” and �
Braz. oral res.. Publicado em: 30/09/2019
-
5. Influence of Abutment Collar Height and Implant Length on Stress Distribution in Single Crowns
Resumo Este estudo avaliou a influência da altura da porção transmucosa do pilar protético com junção cone morse e do comprimento dos implantes no comportamento biomecânico coroas unitárias com diferentes proporção coroa-implante. Seis modelos virtuais (S11, M11, L11, S13, M13 e L13) foram construídos combinando pilares protéticos com transmucoso
Braz. Dent. J.. Publicado em: 03/06/2019
-
6. Failure Probability, Stress Distribution and Fracture Analysis of Experimental Screw for Micro Conical Abutment
Resumo O objetivo deste estudo foi avaliar a probabilidade de falha de dois tipos de parafusos para pilar protético após a compressão e analisar a distribuição da tensão com o método dos elementos finitos. Sessenta (60) restaurações unitárias foram montadas em implantes de titânio (e-fix, A.S. Technology - Titanium Fix). Os grupos foram divididos
Braz. Dent. J.. Publicado em: 04/04/2019
-
7. Morse taper performance: A finite element analysis study
OBJECTIVES: To evaluate and compare the magnitude and distribution of stresses generated on implants, abutments and first molar metal-ceramic crowns using finite element analysis. METHODS: Preliminary three-dimensional models were created using the computer-aided design software SolidWorks. Stress and strain values were observed for two distinct virtual mo
Clinics. Publicado em: 25/03/2019
-
8. Influence of implantoplasty on stress distribution of exposed implants at different bone insertion levels
Abstract This study evaluated the effect of implantoplasty on different bone insertion levels of exposed implants. A model of the Bone Level Tapered implant (Straumann Institute, Waldenburg, Switzerland) was created through the Rhinoceros software (version 5.0 SR8, McNeel North America, Seattle, WA, USA). The abutment was fixed to the implant through a reten
Braz. oral res.. Publicado em: 07/12/2017
-
9. Analyses of Biofilm on Implant Abutment Surfaces Coating with Diamond-Like Carbon and Biocompatibility
Resumo O objetivo deste trabalho foi avaliar a energia livre de superfície (ELS), molhabilidade e propriedades de superfície assim como propriedades antimicrobianas, de adesão e biocompatibilidade de superfícies recobertas com Diamond-Like Carbon (DLC). Além disso, investigou-se a infiltração de Escherichia coli por meio da interface abutment-implante
Braz. Dent. J.. Publicado em: 2017-06
-
10. Misfit and fracture load of implant-supported monolithic crowns in zirconia-reinforced lithium silicate
Abstract Zirconia-reinforced lithium silicate (ZLS) is a ceramic that promises to have better mechanical properties than other materials with the same indications as well as improved adaptation and fracture strength. Objective In this study, marginal and internal misfit and fracture load with and without thermal-mechanical aging (TMA) of monolithic ZLS and
J. Appl. Oral Sci.. Publicado em: 2017-06
-
11. Prosthetic abutment influences bone biomechanical behavior of immediately loaded implants
Abstract This study aimed to evaluate the influence of the type of prosthetic abutment associated to different implant connection on bone biomechanical behavior of immediately and delayed loaded implants. Computed tomography-based finite element models comprising a mandible with a single molar implant were created with different types of prosthetic abutment
Braz. oral res.. Publicado em: 31/05/2016
-
12. Effects of different torque levels on the implant-abutment interface in a conical internal connection
Abstract The fit of the implant-abutment interface was assessed by the metallographic technique and by scanning electron microscopy (SEM), using solid abutment types at different torque levels. Forty Morse taper connections and forty solid abutments were used at different torque levels (repeated after 10 minutes) in the following groups (n = 10): 25 Ncm (gro
Braz. oral res.. Publicado em: 15/03/2016