Dental Implant Endosseous
Mostrando 1-6 de 6 artigos, teses e dissertações.
-
1. Analise histologica e histomorfometrica do reparo osseo perimplantar em cães submetidos a instalação de implantes endosseos com um modelo de carga precoce em dois diferentes desenhos de implantes / Histological and histomorphometric analysis of perimplant osseous repair in dogs submitted to endosseous implant installation with early load model in two different implant design
Several treatment types using prosthesis over implants have been reported, being the singles immediate loading therapy with more controversy. The meaning of the present study is established the characteristics of bone repair in dental implant submitted to immediate loading. It was performed a experimental model using dogs to value two different installations
Publicado em: 2009
-
2. Analyze fotoelastic the distribution of tensions in osseointegrables implants of different designs / Analise fotoelastica da distribuição de tensões em implantes osseointegraveis com diferentes desenhos
O objetivo deste estudo foi analisar qualitativa e quantitativamente a distribuição das tensões geradas em modelos fotoelásticos após a aplicação de cargas verticais de 150N, em implantes osseointegráveis de diferentes desenhos. Foram selecionados 3 implantes: I.) Serson Implant 3,75 x 13 mm, Hexágono Externo; II.) Colosso RC 4,0 x 13 mm, Hexágono
Publicado em: 2009
-
3. Influence of dental implant design on tensions distribution after vertical and oblique loading : a structural and phtoelactic study / Influencia do desenho dos implantes endosseos na distribuição de tensões apos aplicação de cargas verticais e obliquas : analise estrutural e fotoelastica
Este estudo teve como objetivo analisar a influência do desenho dos implantes endósseos na distribuição de tensões geradas nos modelos fotoelásticos após aplicação de cargas verticais e oblíquas a 7,5N, em quatro marcas comerciais de implantes endósseos. Foram selecionados doze implantes, divididos em quatro grupos: I.) Máster Conect Cônico1 4,3
Publicado em: 2008
-
4. Efeito do numero de ciclos de união e separação dos componentes sobre a retenção de sistemas de encaixes para overdentures / Retention force and fatigue strength of overdenture attachment system
The aim of the present study was to evaluate the effect of the number of insertion and removal cycles on retention force of four Overdenture bar-clip attachment systems. Sample included 40 specimens which were assigned to 4 groups (n=10): 1- Conexão Sistemas de Prótese (polymeric clip); 2- Sterngold-Implamed (polymeric clip); 3- 3i- Implant innovation (met
Publicado em: 2007
-
5. In vitro analysis of bacterial leakage and the implant/abutment interface adaptation of systems of endosseous implants / Analise "in vitro" da infiltração bacteriana e das adaptações na interface implante/conector protetico de sistemas de implantes endosseos
O propósito deste estudo foi avaliar in vitro a contaminação bacteriana através da interface implante/conector protético de quatro marcas comerciais de implantes endósseos de titânio comercialmente puro, buscando correlacioná-la com as dimensões dos microespaços e das adaptações na referida interface. Todos os sistemas empregados foram de fabrica
Publicado em: 2006
-
6. In vitro and in vivo electrochemical studies of nickel-chromium-molybdenum-titanium alloy applied to oral implant suprastructures / Estudos eletroquímicos in vitro e in vivo da liga níquelcromomolibdênio titânio aplicada em supraestruturas de implantes orais
The electrochemical behavior of the nickel-chromium-molybdenum-titanium (Ni-Cr-Mo-Ti) alloy was studied and compared to a gold-platinum-palladium (Au-Pt-Pd) alloy in 0.15 mol.L -1 NaCl medium at 36.5ºC. In vitro studies also involved the electrochemical titanium characterization since these alloys are employed in osseointegrated implant suprastructures. In
Publicado em: 2005