1. Optimum design of steel columns filled with concrete via genetic algorithm: environmental impact and cost analysis
Abstract The use of concrete-filled tubular columns as part of structural systems has steadily increased throughout the years. The growing demand for structural elements of this nature is a direct result of the possibility to use various cross-section shapes that have increased strength, along with resistance to fire and other corrosive agents. The main obje
REM - International Engineering Journal. Publicado em: 2022
-
2. Fire response of a 3D multi-storey building with buckling restrained braces
Abstract This paper investigates the performance of a three-dimensional multi-storey structure with Buckling Restrained Brace system (BRBs) under fire condition, using a sequentially coupled nonlinear thermal stress analysis. Efficiency of using BRBs in enhancing the strength and stiffness of a structural frame is compared with that of Ordinary Concentricall
Lat. Am. j. solids struct.. Publicado em: 2015-11
-
3. Pilares de concreto armado em situação de incêndio submetidos à flexão normal composta. / Reinforced concrete columns in fire under uniaxial bending.
According to Brazilian Codes, reinforced concrete structures must be verified under high temperatures, in order to assure the load bearing capacity to allow the safe evacuation of the users and the fire fighting and to reduce the fire spread to other compartments. For reinforced concrete structures, the columns must be analyzed carefully. The significant red
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 06/05/2011
-
4. Inelastic analysis of semi-rigid composite structures under fire conditions
This paper presents the application of a proposed numerical approach, denoted as SAAFE Program (System for Advanced Analysis for Fire Engineering), developed to provide an inelastic analysis of steel and composite (steel-concrete) 2D semi-rigid framed-structures under fire conditions. The proposed structural model allows an accurate description of the struct
Journal of the Brazilian Society of Mechanical Sciences and Engineering. Publicado em: 2011-12
-
5. Avaliação de pilares de concreto armado colorido de alta resistência, submetidos a elevadas temperaturas. / Evaluation of reinforced HSCC columns at high temperature.
Apesar da quantidade de variáveis envolvidas, ainda persiste uma dúvida na comunidade acadêmica sobre o comportamento do concreto de alta resistência em situação de incêndio, considerando-o como mais ou menos suscetível à ocorrência do fenômeno de desplacamento (spalling) tipo explosivo. Em parte, essa dúvida decorre do fato de que, muitas vezes,
Publicado em: 2011
-
6. Desenvolvimento e avaliação da atividade e farmacocinética de nanopartículas lipídicas sólidas contendo a associação de quinina e doxiciclina / Development and evaluation of the activity and pharmacokinetics of solid lipid nanoparticles loaded with the association of Quinine and Doxycycline
Malaria is one of the most devastating tropical diseases caused by intracellular protozoan parasites of the genus Plasmodium. More than 3 billion people live in malarial endemic regions. Five species of Plasmodium (falciparum, vivax, ovale, malariae and knowlesi) cause disease in humans and infection with P. falciparum, the most deadly of these parasites, re
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 2011
-
7. Colunas mistas esbeltas de aço preenchidas com concreto de alta resistencia em temperatura ambiente e em situação de incendio / Mixed slender steel columns filled with high strenght concrete in room temperature and fire situation
In this work, it was investigated in laboratory the effect of fire in slender steel columns unfilled and filled with high strength concrete submitted to three different levels of axial load (30%, 50% and 70%), which is the relation between the axial load to be applied in fire situation and the ultimate load obtained in the column test to room temperature. So
Publicado em: 2009
-
8. Eurocode structural fire design and its application for composite circular hollow section columns
The tabular structural fire design method for centrally loaded composite columns consisting of concrete filled steel circular hollow sections proposed in EN 1994-1-2:2005 (Eurocode 4: Design of Composite Steel and Concrete Structures - Structural Fire Design) is described here. A design procedure is then discussed, based on the determination of the temperatu
Journal of the Brazilian Society of Mechanical Sciences and Engineering. Publicado em: 2008-03
-
9. Experimental study about the fire effect in short composite column of steel and concrete / Estudo experimental do efeito do fogo em pilares mistos de aço e concreto
The use of circular hollow steel filled with concrete as columns are of great importance in the structural area, because it allows steel tube and concrete working together, providing a greater capacity resistant and a longer fire exposure, in relation to the same materials analyzed separately. This work will provide technical information for understanding th
Publicado em: 2008
-
10. Estudo sobre os criterios de dimensionamento de pilares mistos de aço e concreto / Study about formulations to design the composite columns
ln the past, steel-concrete composites were used in building construction just as a way of increasing the strength against corrosion and fire. Later, because of the evolution of construction through higher and higher buildings the technical community was led to develop calculation techniques that considered steel and concrete working together - the steel con
Publicado em: 2006
-
11. Drenagem de espumas usadas em incendios classe B : influencia da presença de polimeros redutores de atrito hidrodinamico
Poly(ethylene oxide), PEO, is one of the most efficient drag reducing polymers. Its application in foam jels for fire-fighting can improve and even assure the fighting efficiency. In order to evaluate the viability of the application of PEO in foams of high stability used in class B fires (inflammable liquids), the effect of the polymer on the stability of f