Estudo sobre os criterios de dimensionamento de pilares mistos de aço e concreto / Study about formulations to design the composite columns

AUTOR(ES)
DATA DE PUBLICAÇÃO

2006

RESUMO

ln the past, steel-concrete composites were used in building construction just as a way of increasing the strength against corrosion and fire. Later, because of the evolution of construction through higher and higher buildings the technical community was led to develop calculation techniques that considered steel and concrete working together - the steel contributing with high resistance and lightness and the concrete with its stiffness and inertia. The growing demand in use of steel-concrete composite columns has motivated deeper studies to represent its behavior with the aim of obtaining more secure and more economic columns. Nowadays, with the advance of computation methods and construction of higher and higher buildings, we have other factors, such as creep, confining, retraction and the adherence, which can establish a limit in the calculation of composite columns. In this way, motivated by different borderlines of global and local slender made compulsory by rules, the paper tries to discuss different formulations present on NBR14323 (1999), EUROCODE 4 (2004), AISC/LRFD (2005). The hypotheses that took the respective formulations are presented and evaluated according to the conditions of work in Brazil. Some numerical examples are presented and discussed at the end

ASSUNTO(S)

bending construção mista composite column steel flexão (engenharia civil) resistencia de materiais strength colunas concrete aço compression

Documentos Relacionados