Comparação da resistencia mecanica a flexão da fixação interna rigida atraves do uso de parafusos metalicos e reabsorviveis na osteotomia sagital do ramo mandibular : estudo in vitro

AUTOR(ES)
DATA DE PUBLICAÇÃO

2003

RESUMO

The purpose of this study was to evaluate the flexion biomechanical resistance of two internal rigid fixation systems. The study which were mechanically tested in twenty sheep s hemimandibles, divided in two groups of ten in each. All mandibles were subjected to a ramus sagittal split osteotomy, followed by an advancement of 5 mm. The samples were measured to avoid discrepancies between them. Group A were fixed by three reabsorbable screws of 2.0 X 12 mm (Bionx Implants®, Tampere, Finland), inserted in positional way and disposed in inverted "L". The same happened in-group B, which were used metallic screws (Osteomed® CO. Addison, Texas - USA), with the same dimensions and design. The results showed no significant statistical difference between the groups. The reabsorbable system tested proved to be a viable alternative when compared to the metallic one