2017-09

Fracture Toughness and Charpy CVN Data for A36 Steel with Wet Welding

Abstract This study presents KIC data obtained from KIC-CVN correlations from Charpy CVN values. For this study, T-welded connections were manufactured from ASTM A36 and E6013 electrodes in dry conditions. Then, a rectangular grinding at the weld toe was carried out and filled with wet welding. Charpy specimens were extracted to obtain CVN values. An exhaustive search through the literature of several authors was performed to collect experimental CVN data about wet welding being applied to A36 steel for comparison with CVN data obtained in this study. By using Charpy impact energy (CVN), KIC v...