04/10/2018

Clinical wear of approximal glass ionomer restorations protected with a nanofilled self-adhesive light-cured protective coating

Abstract High viscous glass ionomer cement (GIC) has gained popularity as a restorative material; however, high wear is pointed as one of the major drawbacks of this material. Protective surface coatings were developed to protect GIC from water contamination with the additional advantage of occluding any surface cracks or porosities commonly found in this material, possibly resulting in an increased wear resistance of the restorations. Objective: The objective of this study was to investigate the clinical wear of GIC approximal restorations in primary molars protected either with a nanofilled...

Texto completo