Steel Concrete Composite Beam
Mostrando 1-12 de 35 artigos, teses e dissertações.
-
1. Composite floor system with CFS trussed beams, concrete slab and innovative shear connectors
Abstract Steel and concrete floor systems are widely applied for buildings and provide excellent structural response, optimized material consumption, reduced beam height, and improved bending strength and stiffness capacity. In recent years, many experimental investigations concerned with new alternatives addressed to efficient interaction between steel and
REM, Int. Eng. J.. Publicado em: 2020-03
-
2. Post-elastic Deformation Characteristics of Hybrid Fibre Reinforced Concrete Composites
Abstract The present study was focused on evaluating the strength and failure properties of hybrid micro-fibre concretes containing micro brass and steel fibre additions. Experimental tests were conducted on different hybrid fibre concretes containing aligned fibres in the direction of beam axis and the relative mechanical performance was compared to randoml
Lat. Am. j. solids struct.. Publicado em: 10/01/2020
-
3. Optimized dimensioning of steel-concrete composite beams
Resumo As seções mistas de aço e concreto estão cada vez mais sendo utilizadas na construção civil, tanto no cenário mundial quanto no Brasil. O trabalho conjunto do perfil de aço e da laje de concreto aumenta consideravelmente o desempenho do elemento estrutural misto devido ao aproveitamento das vantagens de cada material. Neste trabalho, é utiliz
Rev. IBRACON Estrut. Mater.. Publicado em: 13/12/2019
-
4. Nonlinear numerical analysis of composite slabs with steel decking
Resumo O comportamento das lajes mistas é governado pelo cisalhamento longitudinal na interface entre o aço e o concreto, que é desenvolvido em lajes sob flexão simples. O método m-k e o método da interação parcial, utilizados no cálculo da resistência ao cisalhamento na interface aço-concreto de lajes mistas, são baseados em ensaios experimentai
Rev. IBRACON Estrut. Mater.. Publicado em: 11/11/2019
-
5. Experimental evaluation on the structural behavior of truss shear connectors in composite steel-concrete beams
Resumo As estruturas mistas apresentam grandes vantagens quanto a aspectos estruturais e construtivos, sendo os conectores de cisalhamento determinantes para a obtenção da interação entre os elementos estruturais e para a distribuição dos esforços na estrutura, aproveitando-se de forma efetiva da potencialidade de cada material constituinte da estrutu
Rev. IBRACON Estrut. Mater.. Publicado em: 11/11/2019
-
6. Some Aspects of Numerical Modeling of Steel-Concrete Composite Beams with Prestressed Tendons
Abstract Aspects about the numerical modeling of three-dimensional prestressed steel-concrete composite beams by using the finite element (FE) method are highlighted and commented in this work. Emphasis is given to the numerical treatment of bonded and unbonded tendons. The proposed modeling technique uses curved beam and catenary elements for simulating int
Lat. Am. j. solids struct.. Publicado em: 15/08/2019
-
7. Plate with holes as shear connector in cold formed steel composite beams
Resumo Buscando compatibilizar as estruturas em perfil formado a frio com os sistemas de piso com pré-laje, foi proposta nesse trabalho uma alternativa de conector de cisalhamento para vigas mistas compostas por perfil formado a frio que visa maximizar a área disponível para apoio das pré-lajes durante o processo construtivo. Trata-se de um conector em c
Rev. IBRACON Estrut. Mater.. Publicado em: 18/07/2019
-
8. Structural Behaviour of Cold-Formed Steel of Double C-Lipped Channel Sections Integrated with Concrete Slabs as Composite Beams
Abstract Cold-formed steel (CFS) construction is widely recognised as an important contributor to sustainability and green construction. Thus, the use of CFS construction is encouraged and had been advanced by innovations in its structural applications. One such innovation that has recently gained popularity is the use of CFS sections in composite constructi
Lat. Am. j. solids struct.. Publicado em: 27/06/2019
-
9. An interface element for numerical analysis of flat plate/shell elements with deformable connection
Abstract The use of numerical methods such as the finite elements method for solving structural analysis problems is becoming ever more efficient. An interface element capable of associating flat plate/shell element in three different combinations has been developed. In a structural analysis, when only the flat plate/shell’s finite elements are used in th
Lat. Am. j. solids struct.. Publicado em: 26/04/2018
-
10. Bolted Shear Connectors Performance in Self-Compacting Concrete Integrated with Cold-Formed Steel Section
Abstract In conventional composite construction involving hot-rolled steel section, the composite action is usually achieved by using conventional headed shear studs connectors. However, use of headed studs is not practical for cold-formed steel (CFS) section due to its very thin form that is difficult to weld. A suitable bolt and nut type shear connector wa
Lat. Am. j. solids struct.. Publicado em: 2016-04
-
11. Finite element implementation for the analysis of 3D steel and composite frames subjected to fire
This paper presents a finite element formulation for the numerical analysis of three-dimensional framed steel, reinforced concrete or composite steel and concrete structures subjected to fire. Several specialized and commercial programs may be used for the analysis of structures in fire condition. Within this context, the purpose of this work is to present t
Lat. Am. j. solids struct.. Publicado em: 2014-01
-
12. Modelos numéricos de vigas mistas de aço e concreto pertencentes a sistemas de pisos mistos de pequena altura em situação de incêndio / Numerical modelling of composite slim floor beams in fire
Slim floor frames consists on structural system in which the steel beam is completely or partially inserted in a concrete slab, that is usually used in profiled steel decks systems. The main goal of the slim floor systems is to obtain a minimum height of the composite beam section and, consequently, achieve a higher height of the floor or a lower total heigh
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 08/03/2012