Implant Abutment Connection Implant Abutment Interface
Mostrando 1-10 de 10 artigos, teses e dissertações.
-
1. Does the implant-abutment interface interfere on marginal bone loss? A systematic review and meta-analysis
Abstract The objective of this systematic review was to compare the conical internal connection (IC) with the external hexagonal connection (EH) on the occurrence of marginal bone loss (ΔMBL). Different databases were used to carry out the selection of the elected studies. The studies were judged according to the risk of bias as “high”, “low” and �
Braz. oral res.. Publicado em: 30/09/2019
-
2. Effects of different torque levels on the implant-abutment interface in a conical internal connection
Abstract The fit of the implant-abutment interface was assessed by the metallographic technique and by scanning electron microscopy (SEM), using solid abutment types at different torque levels. Forty Morse taper connections and forty solid abutments were used at different torque levels (repeated after 10 minutes) in the following groups (n = 10): 25 Ncm (gro
Braz. oral res.. Publicado em: 15/03/2016
-
3. Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla / Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila
The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthe
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 02/08/2012
-
4. Estudo in vitro de um material para selamento da interface implante-intermediário do tipo minipilar cônico em implantes de hexágono externo, hexágono interno e cone morse / In vitro sealing of a material of implant-abutment interface of mini conical pillar: inimplant external hexagon, internal hexagon and Morse taper
Microbial and fluidic leakage in the implant-abutment interface are shown in literature through a variety of studies, accusing the space that exists between the components of the implant, called \"GAP\", which seems to be the source of the microorganism infiltration, either from the external to the internal environment or the inverse, resulting in inflammato
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 08/05/2012
-
5. Análise tridimensional por elemento finito do comportamento biomecânico de próteses totais fixas implantossuportadas : efeito do tipo de conexão protética, cargas oclusais e número de implantes / Three-dimensional finite element analysis of biomechanics of implant-supported fixed prostheses : effect of connection system, occlusal load, and number of implants
The purpose of this study was to analyze the stress and strain distribution by three-dimensional finite element method in implant supported fixed prostheses and peri-implantar bone region, using two types of implant-abutment connection internal and external, correlated to the effect of axial loadings and number of implants. Virtual models were developed by s
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 15/04/2011
-
6. Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment
OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cas
Journal of Applied Oral Science. Publicado em: 2011-02
-
7. Análise tridimensional por elementos finitos da biomecânica de próteses implantossuportadas : influência da carga oclusal, tipo de conexão, angulação dos implantes e simplificações de modelagem / Tridimensional finite element analysis of biomechanics of implant-supported prosthesis : influence of occlusal load, implant connection system, implant tilting and modeling simplifications
O objetivo nos presentes estudos foi avaliar, por meio de análise tridimensional de elementos finitos, os efeitos nos valores e padrões de distribuição de tensões de modelo virtuais de próteses implantossuportadas na presença de: 1) Simplificações de modelagem das geometrias de superfícies com rosca; 2) Variação do padrão de cargas oclusais e ti
Publicado em: 2011
-
8. Preload loss and bacterial penetration on different implant-abutment connection systems
A perda da pré-carga pode favorecer o desajuste da interface implante-pilar e a colonização bacteriana nesta interface pode levar a perda de implantes. O objetivo deste estudo foi avaliar a perda de pré-carga e a infiltração bacteriana através da interface implante-pilar de sistemas de conexão cônica e hexágono externo, submetidos à ciclagem térm
Brazilian Dental Journal. Publicado em: 2010
-
9. Avaliação da infiltração microbiana na interface implante-abutment em conexões tipo hexágono interno e cone-morse de implantes osseointegráveis / Evaluation of bacterial leakage at implant abutment interfaces of implants wiht internal hexagonal
The scientific literature has reported that dental implants can be affected by the oral microorganisms through the formation of a bacterial biofilm. The region most affected is the connection between the implant platform and the prosthetic abutment, particularly in implants with an external connection. Therefore, the region of the implant/abutment connection
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 28/09/2007
-
10. Avaliação da infiltração microbiana na interface implante-abutment em conexões tipo hexágono interno e cone-morse de implantes osseointegráveis / Evaluation of bacterial leakage at implant abutment interfaces of implants wiht internal hexagonal
A literatura tem ressaltado que os implantes osseointegráveis podem ser afetados por transtornos decorrentes da formação de biofilme bacteriano em sua superfície. A região acometida envolve principalmente a conexão entre a plataforma do implante e o abutment, situação evidenciada especialmente nos implantes de conexões externas. Assim, tal situaçã
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 28/09/2007