Mostrando 13-24 de 51 artigos, teses e dissertações.
-
13. Estudo da influência de partículas de ouro na dose absorvida em tecido mole utilizando dosimetria com gel polimérico / Study of the influence of gold particles on the absorbed dose in soft tissue using polymer gel dosimetry
The presence of high-Z material adjacent to soft tissue, when submitted to irradiation, enhances locally the absorbed dose in these soft tissues. Such effect occurs due to the outscattering of photoelectrons from the high-Z material. Polymer gel dosimeters have been used to investigate this effect. Analytic calculations to estimate the dose enhancement and M
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 04/10/2011
-
14. Avaliação de dosímetros termoluminescentes para uso em radioterapia com fótons de alta energia / Evaluation of thermoluminescent dosimeters for using in radiotherapy with high energy photons
Atualmente a maior parte dos tratamentos radioterápicos é feita através de irradiações com feixes de fótons de alta energia. Esses feixes se originam em fontes radioativas (de nuclídeos como o cobalto 60) ou são gerados em aceleradores lineares de elétrons. Para as medidas dosimétricas nesses feixes, uma das técnicas mais utilizada é a termolumin
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 25/08/2011
-
15. Retrieval of GammaCell 220 irradiator isodose curves with MCNP simulations and experimental measurements
Gamma irradiator facilities can be used in a wide range of applications such as biological and chemical researches, sterilization of medical devices and products. Dose mapping must be performed in these equipments in order to establish plant operational parameters, as dose uniformity, source utilization efficiency and maximum and minimum dose positions. The
Brazilian Journal of Physics. Publicado em: 2010-03
-
16. Determination of dosimetric quantities of interest in Mammography using thermoluminescent detectors. / Determinação de grandezas dosimétricas de interesse em mamografia usando detectores termoluminescentes
National and international health organizations such as the Brazilian Ministry of Health, through its Secretary of Health Surveillance establishes in the publication Nº 453/98 that in all mammographic equipments must be evaluated the entrance-skin dose through the readings of an ionization chamber-electrometer system corrected by the backscatter factor, amo
Publicado em: 2010
-
17. Desenvolvimento de dosímetros com diodos de Si resistentes à radiação para dosimetria de altas doses / Development of dosimeters with rad-hard silicon diodes for high dose dosimetry
Neste trabalho são apresentados os resultados obtidos com diodos resistentes a danos de radiação dos tipos fusão zonal padrão (FZ), fusão zonaI com difusão de oxigênio (DOFZ) e Czochralski magnético (MCz) em dosimetria de processamento por radiação gama. Estes dispositivos de junção p+-n-n+ foram manufaturados por Okmetic Oyj. (Vantaa, Finland)
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 31/08/2009
-
18. Dosimetria de processos de irradiação gama com diodos comerciais de silício / GAMMA RADIATION PROCESSING DOSIMETRY WITH COMMERCIAL SILICON DIODES
This work envisages the development of dosimeters based on Si diodes for gamma radiation dosimetry from 1 Gy up to 100 Gy. This dose range is frequently utilized in radiation processing of crystal modifications, polymers crosslinking and biological studies carried out in the Radiation Technology Center at IPEN-CNEN/SP. The dosimeter was constructed by a comm
Publicado em: 2009
-
19. Estudo comparativo entre métodos de calibração de aplicadores clínicos de radiação beta / COMPARATIVE STUDY AMONG CALIBRATION METHODS OF CLINICAL APPLICATORS OF BETA RADIATION
90Sr+90Y clinical applicators are instruments used in brachytherapy procedures and they have to be periodically calibrated, according to international standards and recommendations. In this work, four calibration methods of dermatological and ophthalmic applicators were studied, comparing the results with those given by the calibration certificates of the ma
Publicado em: 2009
-
20. Influência da radiação gama em filmes de PPV e PTHT: caracterização óptica e elétrica
In this work, we investigated the effects of Gamma ionizing radiation on optical properties of the polyeletrolite poly (chloride Tetrahydrothiophen of xililideno) (PTHT) and the conjugated polymer poly(p- phenylene vinileno) (PPV). The PPV films were processed from PTHT films and it was submitted on the annealing step at low (110oC) and higher (200oC) under
Publicado em: 2009
-
21. CaracterizaÃÃo de diodos com e sem estrutura de mÃltiplos anÃis de guarda para dosimetria de elÃtrons / Characterization of diodes with and without multiple guard rings structure for electron dosimetry
A dosimetria de feixes de elÃtrons de alta energia utilizados em radioterapia à realizada atualmente com cÃmaras de ionizaÃÃo de placas paralelas. Entretanto, devido aos crescentes avanÃos nas tÃcnicas de tratamento utilizadas, detectores com maior resoluÃÃo espacial do que as cÃmaras de ionizaÃÃo sÃo necessÃrios. Os detectores semicondutores p
Publicado em: 2009
-
22. ASSESSMENT OF CaSO4:Dy AND LiF:Mg,Ti THERMOLUMINESCENT DOSIMETERS PERFORMANCE IN THE DOSIMETRY OF CLINICAL ELECTRON BEAM / Avaliação do desempenho dos detectores termoluminescentes de CaSO4:Dy e LiF:Mg, Ti na dosimetria de feixes clínicos de elétrons
The assessment of the performance of CaSO4:Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid w
Publicado em: 2008
-
23. Characterization of semiconductor polymers for use in gamma radiation sensors. / Caracterização de polímeros semicondutores para o uso em sensores de radiação gama.
This work aims the investigation of the optical properties of luminescent polymeric systems when submitted to different gamma radiation doses. Solutions of poly[2-methoxi-5-(2etil-hexiloxi)-p-phenilenevinilene] - MEH-PPV in chloroform were prepared. From those solutions, thin film layers of MEH-PPV were deposited on glass substrates. The polymer solutions an
Publicado em: 2008
-
24. Caracterização do campo de nêutrons na instalação para estudo em BNCT no Reator IEA-R1 / NEUTRON FIELD CHARACTERIZATION IN THE INSTALLATION FOR BNCT STUDY IN THE IEA R1 REACTOR.
This work aims to characterize the mixed neutron and gamma field, in the sample irradiation position, in a research installation for Boron Neutron Capture Therapy (BNCT), in the IPEN IEA-R1 reactor. The BNCT technique has been studied as a safe and selective option in the treatment of resistant cancerigenous tumors or considered non-curable by the convention