Dental Implants Connection
Mostrando 1-12 de 13 artigos, teses e dissertações.
-
1. Morse taper internal connection implants: would abutment reseating influence retention?
Abstract Aim: To investigate whether the removal and reseating of the abutment influences the retention of Morse taper implant system. Methods: Two Morse taper implant systems were selected: Bicon Dental ImplantTM system (Bicon, LLC, Boston, MA, USA) and Kopp Implant(r) system (Kopp(r), Curitiba, PR, Brazil). In both systems, the abutment is connected to
Braz. J. Oral Sci.. Publicado em: 2015-09
-
2. Biomechanical evaluation of subcrestal dental implants with different bone anchorages
This study evaluated the biomechanical influence of apical bone anchorage on a single subcrestal dental implant using three-dimensional finite element analysis (FEA). Four different bone anchorage designs were simulated on a posterior maxillary segment using one implant with platform switching and internal Morse taper connection as follows: 2 mm subcrestal p
Braz. oral res.. Publicado em: 04/08/2014
-
3. Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks (I-Bridge®2) before and after cyclic mechanical loading
Implant-supported screw-retained fixed dental prostheses (FDPs) produced by CAD/ CAM have been introduced in recent years for the rehabilitation of partial or total endentulous jaws. However, there is a lack of data about the long-term mechanical characteristics. OBJECTIVE: The aim of this study was to investigate the failure mode and the influence of exten
J. Appl. Oral Sci.. Publicado em: 2013-07
-
4. Effect of aluminum oxide blasting and use of industrial sealant on the outer abutment surface of the prosthetic morse taper system connection on the untightening torque / Efeito do jateamento de óxido de alumínio e uso de selante industrial, na superfície de pilares protéticos Cone Morse, de restaurações implanto suportadas sobre a resistência ao contratorque
Problemas com desenho de conexões protéticas sobre implantes, microfendas, afrouxamento e, consequentemente, perdas das estruturas protéticas reabilitadoras são tópicos frequentes do estudo odontológico. Conexões do tipo Cone Morse, devido às suas características, diminuíram o índice desses problemas, abrindo uma nova perspectiva para o sucesso da
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 18/06/2012
-
5. Estudo in vitro de um material para selamento da interface implante-intermediário do tipo minipilar cônico em implantes de hexágono externo, hexágono interno e cone morse / In vitro sealing of a material of implant-abutment interface of mini conical pillar: inimplant external hexagon, internal hexagon and Morse taper
Microbial and fluidic leakage in the implant-abutment interface are shown in literature through a variety of studies, accusing the space that exists between the components of the implant, called \"GAP\", which seems to be the source of the microorganism infiltration, either from the external to the internal environment or the inverse, resulting in inflammato
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 08/05/2012
-
6. Análise tridimensional por elemento finito do comportamento biomecânico de próteses totais fixas implantossuportadas : efeito do tipo de conexão protética, cargas oclusais e número de implantes / Three-dimensional finite element analysis of biomechanics of implant-supported fixed prostheses : effect of connection system, occlusal load, and number of implants
The purpose of this study was to analyze the stress and strain distribution by three-dimensional finite element method in implant supported fixed prostheses and peri-implantar bone region, using two types of implant-abutment connection internal and external, correlated to the effect of axial loadings and number of implants. Virtual models were developed by s
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 15/04/2011
-
7. Machined and plastic copings in three-element prostheses with different types of implantabutment joints: a strain gauge comparative analysis
OBJECTIVE: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of hexagonal connection would generate different mic
Journal of Applied Oral Science. Publicado em: 2010-06
-
8. Titanium dental implant surfaces
Osseointegration has been defined as "a direct structural and functional connection between ordered, living bone and the surface of a load-carrying implant". However, titanium and its alloys cannot directly bond to living bone after being implanted into the body. The osseointegration of titanium dental implants is critically dependent on the implant surface
Matéria (Rio de Janeiro). Publicado em: 2010
-
9. Avaliação da infiltração microbiana na interface implante-abutment em conexões tipo hexágono interno e cone-morse de implantes osseointegráveis / Evaluation of bacterial leakage at implant abutment interfaces of implants wiht internal hexagonal
The scientific literature has reported that dental implants can be affected by the oral microorganisms through the formation of a bacterial biofilm. The region most affected is the connection between the implant platform and the prosthetic abutment, particularly in implants with an external connection. Therefore, the region of the implant/abutment connection
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 28/09/2007
-
10. Avaliação da infiltração microbiana na interface implante-abutment em conexões tipo hexágono interno e cone-morse de implantes osseointegráveis / Evaluation of bacterial leakage at implant abutment interfaces of implants wiht internal hexagonal
A literatura tem ressaltado que os implantes osseointegráveis podem ser afetados por transtornos decorrentes da formação de biofilme bacteriano em sua superfície. A região acometida envolve principalmente a conexão entre a plataforma do implante e o abutment, situação evidenciada especialmente nos implantes de conexões externas. Assim, tal situaçã
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 28/09/2007
-
11. Estudo biomecânico da conexão implante/pilar protético em implantes do sistema cone morse / Biomechanical study of the implant/abutment connection in implants with internal tapered connectios
Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in external and internal hex implants. This work presents the results of two studies that investigated the biomechanical properties of the implant/abutment connection in implants with internal tapered connections. The purpose of the first s
Publicado em: 2007
-
12. Parafusos de pilar utilizados em implantes dentários / Pillar screws used in dental implants
Due to the surge and success of bone integrated implants, dental implants have been consolidated as an important rehabilitation technique within the general context of dentistry. Functional force, bio-mechanical compatibility and tension transfer to the neighboring tissues are among the factors envolved in the line of dental implants. In this aspect, one of
Publicado em: 2006