Cr Vi Reduction
Mostrando 1-12 de 46 artigos, teses e dissertações.
-
1. Preparation and application of Zero Valent Iron immobilized in Activated Carbon for removal of hexavalent Chromium from synthetic effluent
RESUMO Diferentemente dos contaminantes orgânicos, os metais pesados não são biodegradáveis e tendem a se acumular nos organismos vivos e também são reconhecidos por serem tóxicos ou carcinogênicos. A utilização de nanopartículas de ferro zero valente (nFVZ) é relatada como uma técnica alternativa e de elevado potencial para remediação in situ
Rev. Ambient. Água. Publicado em: 03/10/2019
-
2. STUDY OF THE CHROMIUM(VI) REMOVAL FROM AQUEOUS SYSTEMS BY COBALT NANOPARTICLES
The cobalt nanoparticles (NPs-Co) were synthesized and applied in the removal of Cr(VI). The obtained nanomaterials presented magnetic properties and were characterized by the techniques of Transmission Electron Microscopy and X-ray diffraction. The NPs-Co, with a diameter of less than 50 nm, had a composition based on metallic cobalt and cobalt oxide. The N
Quím. Nova. Publicado em: 18/07/2019
-
3. Use of Biodiesel Press Cake Waste to Prepare Fe/Carbon Reactive Composites for Environmental Applications: Removal of Hazardous CrVI Contaminants
In this work, Ricinus communis L. press cake waste from biodiesel production was used to produce a versatile reactive material for environmental applications. The biodiesel cake waste was impregnated with FeIII at different concentrations (19-45 wt.%) and treated at 400, 600 and 800 °C. Mössbauer, X-ray diffraction (XRD), thermogravimetric analysis (TG/DTA
J. Braz. Chem. Soc.. Publicado em: 2015-10
-
4. Characterization and Metal Detoxification Potential of Moderately Thermophilic Bacillus cereus from Geothermal Springs of Himalaya
Two thermophilic Bacillus cereus strains (B. cereus-TA2 and B. cereus-TA4) used in the present study were isolated from the geothermal spring of Hunza valley, Gilgit, Pakistan. They showed the ability to withstand and grow at high temperature (85°C). Both these strains could resist multiple metals (copper, cadmium, mercury, manganese, zinc, arsenic, chromiu
Braz. arch. biol. technol.. Publicado em: 2014-08
-
5. Hexavalent chromium reduction by immobilized cells of Bacillus sphaericus AND 303
Bacillus sphaericus AND 303, a Cr(VI)-resistant and reducing bacterium reported from serpentine outcrops of Andaman was evaluated for Cr(VI) reduction using immobilized cells under batch culture. Screening of inert matrices for entrapment of whole cells indicated that polyvinyl alchohol-alginate was the most effective one reducing 87.5% of 20 µM Cr(VI) in 2
Braz. arch. biol. technol.. Publicado em: 2013-06
-
6. Chi-square analysis of the reduction of ATP levels in L-02 hepatocytes by hexavalent chromium
This study explored the reduction of adenosine triphosphate (ATP) levels in L-02 hepatocytes by hexavalent chromium (Cr(VI)) using chi-square analysis. Cells were treated with 2, 4, 8, 16, or 32 μM Cr(VI) for 12, 24, or 36 h. Methyl thiazolyl tetrazolium (MTT) experiments and measurements of intracellular ATP levels were performed by spectrophotometry or bi
Brazilian Journal of Medical and Biological Research. Publicado em: 2012-06
-
7. Evaluatin of metabisulfite and a commercial stee wool for removing chromium (VI) from wastewater.
Efficiency of metabisulfite and a commercial steel wool as reducing agents in the removal of Cr(VI) from wastewaters was evaluated. Chromium( VI) was converted to Cr(III), precipitated with NaOH, and removed by filtration. A reduction of more than 1.0 x 10(5) and 4.0 x 10(5) fold in total Cr and the Cr(VI) concentrations, respectively, was observed by employ
Enviromental Chemistry Letter. Publicado em: 2011
-
8. Estudo da especiaÃÃo do cromo no processo de adsorÃÃo por carvÃo ativado usando a espectroscopia de emissÃo de raios X Kβ / Study of the chromium speciation during the adsorption process on activated carbon as assessed by X-ray Kβ emission spectroscopy
Este trabalho visa estudar a reduÃÃo do cromo hexavalente à forma trivalente atravÃs do processo de adsorÃÃo, avaliada pela espectrometria Kβ de emissÃo. Amostras de carvÃo ativado foram utilizados como material adsorvente, enquanto a resina Amberlite IR 120 foi usada como um indicador da presenÃa de Cr(III) em todas as soluÃÃes contendo Cr(V
Publicado em: 2011
-
9. Redução de cromo hexavalente por bactérias isoladas de solos contaminados com cromo / Reduction of hexavlent chromium by isolated bacteria of contaminated soils with chromium
A redução do Cr(VI) para Cr(III) diminui a toxidade deste metal no ambiente, uma vez que o Cr(III) é insolúvel às membranas biológicas. Assim, a redução microbiana do Cr(VI) é uma alternativa para reduzir os impactos ambientais causados por este metal, utilizado em diversos processos industriais. O objetivo deste trabalho foi selecionar microrganism
Publicado em: 2010
-
10. Uso de Biofiltros para remoção de cromo (VI)
Este trabalho estudou a redução biológica de Cr (VI) e remoção de cromo total em filtro anaeróbio seguido por um biofiltro submerso com aeração intermitente, utilizando cultura mista de micro-organismos. Para o trabalho foram obtidas duas culturas mistas, uma do lodo da AMCOA (Associação dos Manufatores de Couros e Afins do Distrito Industrial de F
Publicado em: 2010
-
11. Sistemas de análises químicas em fluxo explorando multi-impulsão, interface única ou quimiometria / Flow systems exploiting multi-pumping, single interface or chemometry
Multi-pumping flow systems (MPFS) present as an unique feature the use of solenoid pumps as fluid propelling devices, which deliver pulsed flows. This flow regime was evaluated in order to improve mixing conditions between the involved solutions, heating transfer and gas diffusion.The association of the chemometric methods of analysis and MPFS systems was de
Publicado em: 2009
-
12. Redução de cromo hexavalente em filtro biológico de fluxo contínuo
O cromo hexavalente (Cr (VI)) é um metal pesado, altamente tóxico e carcinogênico para seres vivos. É amplamente utilizado em indústrias de diferentes segmentos tais como: siderúrgicas, metalúrgicas, indústrias têxteis, curtumes, usinas nucleares, de galvanoplastia e tintas. Devido à sua ampla aplicação, o cromo hexavalente é encontrado em altas
Publicado em: 2009