Valor do teste de dosagem do Dímero - D plasmático no diagnóstico do tromboembolismo venoso agudo / Value of measure plasmatic D Dimer test to diagnosis of the acute thrombolism venous

AUTOR(ES)
DATA DE PUBLICAÇÃO

2007

RESUMO

Introduction: The thromboembolic disease is a multicausal complex disturb with signals and symptoms that confusing itself with other diseases. Because its gravity strategies search objecting to get a faster diagnosis. The measure plasmatic D dimer test seems to be an alternative for exclusion of the diagnostic of acute venous thromboembolism. Objectives: To evaluate the value of the measure plasmatic D dimer test, using the method Enzyme Linked Fluorescent Assay (ELFA), in the diagnostic of acute venous thromboembolism. Methods: In 89 patients with signals and symptoms suggestive of pulmonary thromboembolism and/or deep vein thrombosis had been carried through measure D dimer by technique ELFA equipment VIDAS® - BioMérieux. The values of sensibility, accuracy specificity, predictive values positive and negative and of the test had been calculated, as well as curve ROC of the sample studied. All the patients had been submitted the image exams for the confirmation of the acute thromboembolism event. It was calculated kappa ratio to compare D dimer test results with image exams results. Results: Between 89 studied patients (mean of age 54.3 years; 51 women), 36 (40.4%) they had presented and 53 had not presented acute thrombosis (59.6%). It enters the patients without acute thromboembolism 15 (28.3%) had presented resulted negative of D dimer. All patients with thrombosis had presented resulted positive of D dimer. The test presented 100% sensibility; 28.3% of specificity; positive predictive value was 48.6%; 100% of negative predictive value and accuracy value was 57.3%. The area under the curve (AUC) to total sample studied was 0.734, it was showed that the test have a good prediction to acute thrombosis. The kappa ratio value was 0.24 (p<0.001) showing a bad concordat n to thrombosis diagnostic. Conclusion: The measure of D dimer by method ELFA was able to exclude the diagnostic of acute venous thromboembolism in this sample studied. The results obtained in this sample studied let to conclude that the D dimer test in patients with suspected of acute thromboembolism presented high sensibility to diagnostic of this disease.

ASSUNTO(S)

tromboembolismo/ diagnóstico pulmonary embolism/diagnostic testes de coagulação sangüínea venous thrombosis/diagnostic. enzyme - linked immunosorbent assay elisa thromboembolism/diagnostic valor preditivo dos testes blood coagulation tests embolia pulmonar/diagnóstico trombose venosa/diagnóstico. predictive value of tests

Documentos Relacionados