True optical resolution beyond the Rayleigh limit achieved by standing wave illumination
AUTOR(ES)
Frohn, Jan T.
FONTE
The National Academy of Sciences
RESUMO
During the last decade, various efforts have been undertaken to enhance the resolution of optical microscopes, mostly because of their importance in biological sciences. Herein, we describe a method to increase the resolution of fluorescence microscopy by illuminating the specimen with a mesh-like interference pattern of a laser source and electronic postprocessing of the images. We achieve 100-nm optical resolution, an improvement by a factor of more than 2 compared with standard fluorescence microscopy and of 1.5 compared with confocal scanning.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=16528Documentos Relacionados
- Beyond the Rayleigh instability limit for multicharged finite systems: From fission to Coulomb explosion
- Spatial resolution of the variable-period x-ray standing-wave method as applied to model membranes.
- SOME FACTORS INFLUENCING THE LONG-WAVE LIMIT OF PHOTOSYNTHESIS
- Beyond the diffusion limit: Water flow through the empty bacterial potassium channel
- Acoustic standing wave suppression using randomized phase-shift-keying excitations