Preliminary Experience with GORE-TEX® Grafting for Right Ventricle-Pulmonary Artery Conduits
AUTOR(ES)
Molina, J. Ernesto
RESUMO
A consecutive series of 12 patients between the ages of 6½ and 37 years underwent implantation of venous ventricle-pulmonary artery conduits. GORE-TEX material without prosthetic valves was used. Four patients had L-transposition of the great vessels with ventricular septal defect (VSD) and pulmonary stenosis; four had tetralogy of Fallot with pulmonary atresia; and one had double outlet right ventricle, pulmonary stenosis, and a complete form of A-V canal. Two patients had D-transposition of the great arteries, VSD, and pulmonary stenosis; and one patient had L-transposition of the great arteries and isolated pulmonary stenosis. All patients had low pulmonary resistance and pressures. The technique for implanting this noncrimped type of prosthesis is described in detail. Follow-up ranged from 2 months to 5½ years.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=324610Documentos Relacionados
- COMBINED EXTENDED RIGHT HEPATECTOMY WITH INFERIOR VENA CAVA RESECTION AND RECONSTRUCTION WITH GORE-TEX GRAFT
- Fifteen years of experience with frontalis suspension using polytetrafluoroethylene (Gore-Tex®) suture in blepharoptosis repair
- Voice Outcome after Gore-Tex Medialization Thyroplasty
- Transannular GORE-TEX Patch with Pericardial Unicusp for Total Correction of Tetralogy of Fallot