Interfacial Properties and Bottom/Top Hardness Ratio Produced by Bulk Fill Composites in Dentin Cavities

AUTOR(ES)
FONTE

Braz. Dent. J.

DATA DE PUBLICAÇÃO

07/10/2019

RESUMO

Resumo O objetivo deste estudo foi avaliar a resistência de união, razão base/topo de microdureza, adaptação marginal e nanoinfiltração interfacial de resinas compostas bulk fill (BF) e tradicional (RT) de viscosidade regular.: Duas BF (Filtek Bulk Fill e Aura Bulk Fill) e duas RT (Filtek Z250XT e Aura) foram testados. Quarenta cavidades cônicas (4,8×2,8×4,0) foram preparadas em dentina bovina e restauradas com os compósitos (n=10). Depois de 24 h em água, a adaptação marginal foi avaliada por meio do corante com detector de cárie. As faces de topo e base das restaurações cônicas foram coradas por cinco segundos e a porcentagem de fendas na interface compósito/dentina foi determinada utilizando-se imagens analisadas num programa (ImageTool). A microdureza Vickers foi mensurada e a razção base/topo de microdureza (B/T) foi determinada. A resistência de união por push-out foi executada numa máquina de ensaios universal (0,5mm/min) e o padrão de fratura avaliado num estereomicroscópio (20x). Espécimes adicionais (n=3) foram confeccionados para avaliação da nanoinfiltração interfacial. Os dados foram analisados por meio de ANOVA a dois fatores e teste de Tukey (a=0,05). A porcentagem de fendas foi maior na base que no topo. A B/T da Aura Bulk Fill foi estatisticamente menor que os demais compósitos. A resistência de união por push-out foi similar entre os compósitos. As BF apresentaram menos nanoinfiltração que as RT na base das restaurações cônicas e não houve diferenças entre os materiais no topo. Conclui-se que a Filtek Bulk Fill comportou-se melhor que a Aura Bulk Fill considerando-se as propriedades analisadas.Abstract The aim of this study was to evaluate the bond strength, bottom/top hardness ratio, marginal adaptation, and interfacial nanoleakage of regular viscosity bulk fill composites (RVBFC) and regular viscosity traditional composites (RVTC). Two RVBFC (Filtek Bulk Fill and Aura Bulk Fill) and two RVTC (Filtek Z250XT and Aura) were assessed. Forty conical cavities (4.8×2.8×4.0) were prepared in bovine dentin and restored with composites (n=10). After 24h in water, marginal adaptation was evaluated by staining with a caries detector. The top and bottom surfaces of the conical restorations were stained for five seconds and the gap percentage in the composite/dentin interface was determined using digital images on a measurement program (ImageTool). The Vickers microhardness was measured and the bottom/top microhardness ratio (B/T) was determined. Push-out bond strength test was performed in a universal testing machine (0.5mm/min) and failure modes were evaluated in a stereomicroscope (20×). Other specimens (n=3) were produced for interfacial nanoleakage evaluation. Data were analyzed using one and two-way ANOVA and Tukey’s test (α=0.05). The gap percentage was higher in the bottom compared to the top. The B/T ratio of the Aura Bulk Fill was statistically lower than other composites. Push-out bond strength were similar among composites. The RVBFC presented lower nanoleakage than the RVTC in the bottom of the conical restoration and there was no difference among the materials in the top surfaces. In conclusion, Filtek Bulk Fill performed better than Aura Bulk Fill regarding the analyzed properties.

Documentos Relacionados