Evaluation of thermal disinfection procedures for hydrophilic contact lenses.
AUTOR(ES)
Busschaert, S C
RESUMO
The kinetics and efficacy of moist heat disinfection for hydrophilic contact lenses were investigated by using representative microorganisms of ophthalmic concern and several heat-resistant species. In replicate challenges, 80 degrees C for 10 min and 75 degrees C for 5 min were proven efficacious for moist-heat disinfection.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=242888Documentos Relacionados
- Sterilization of hydrophilic contact lenses.
- Calcium deposition as a cause of spoilation of hydrophilic soft contact lenses.