Estudos de marcação do etidronato com 188Re proveniente de diferentes geradores de 188W/ 188Re / Studies of HEDP labelled with 188Re from different generators of 188W / 188Re.

AUTOR(ES)
DATA DE PUBLICAÇÃO

2006

RESUMO

The widespread interest in 188Re for therapeutic applications, is due to its attractive 16,9 hours half-life, emission of a βֿ particle with maximum energy of 2.12 MeV and gama-ray of 155 keV suitable for imaging. This work presents the radiollabeling of HEDP (etidronate) with 188Re eluted from alumina-based 188W/188Re generators and tungstate-based 188W/188Re gel generators. Dependence of the yield of the 188Re-HEDP on the concentration of the reduction agent, pH, reaction time, temperature and addition of carrier Re2O7 were evaluated. The radiollabeling of 188Re-HEDP procedure using the optimum conditions resulted a yield ≥ 98% for liquid and lyophilized kits. This basic formulation contains: 30 mg de HEDP, 7 mg de SnCl2, 3 mg de ascorbic acid and addition of 20 μg of Re2O7. The reactions were carried out with heating in boiling water for 30 minutes followed by 60 minutes of incubation. Another important aspect of this work was the radiochemical quality control compairing the results of PC, TLC and ion chromatography, along with the experiments with HPLC. The biological distribution proved the adequate bone uptake and in vivo stability of 188Re-HEDP complexes.

ASSUNTO(S)

etidronato gerador labelled hedp radiollabeling generators radiomarcacao renio-188 rhenium-188