Desenvolvimento e validação de método por cromatografia líquida de alta eficiência para determinação simultânea das impurezas timina e timidina na matéria-prima estavudina

AUTOR(ES)
FONTE

Química Nova

DATA DE PUBLICAÇÃO

2008

RESUMO

A HPLC method was developed to quantify thymine and thymidine impurities in stavudine bulk drug. The separation was carried out in isocratic mode using methanol/water (20:80) as mobile phase, a C18 column and UV detection at 266 nm. The method provided selectivity based on peak purities and resolution among peaks. It was linear over the range of 0.5-5.0 µg/mL. The quantitation limits were 0.021 µg/mL for thymine and 0.134 µg/mL for thymidine. The average accuracies of three concentrations ranged from 97.06 to 102.61% and precision was close to 1%. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.