Buckling of Slender Concrete-Filled Steel Tubes with Compliant Interfaces
AUTOR(ES)
Schnabl, Simon, Planinc, Igor
FONTE
Lat. Am. j. solids struct.
DATA DE PUBLICAÇÃO
2017-10
RESUMO
Abstract This paper presents an exact model for studying the global buckling of concrete-filled steel tubular (CFST) columns with compliant interfaces between the concrete core and steel tube. This model is then used to evaluate exact critical buckling loads and modes of CFST columns. The results prove that interface compliance can considerably reduce the critical buckling loads of CFST columns. A good agreement between analytical and experimental buckling loads is obtained if at least one among longitudinal and radial interfacial stiffnesses is high. The parametric study reveals that buckling loads of CFST columns are very much affected by the interfacial stiffness and boundary conditions.
Documentos Relacionados
- Numerical study of concrete-filled steel composite (CFSC) stub columns with steel stiffeners
- Behaviour of stiffened concrete-filled steel composite (CFSC) stub columns
- Temperature field of concrete-filled steel tubular columns in fire
- Estudo da aderência aço-concreto em pilares mistos preenchidos
- Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns