Beer Clarification with polysulfone membrane and study on fouling mechanism
AUTOR(ES)
Oliveira, Ricardo Cardoso de, Barros, Sueli Teresa Davantel de
FONTE
Brazilian Archives of Biology and Technology
DATA DE PUBLICAÇÃO
2011-12
RESUMO
The aims of the present work were to study the relationship between the fluxes, permeate quality, and fouling mechanism. A polysulfone membrane with 100 KDa and 0.12 m² of surface area was used. Permeate fluxes were measured for different pressures (0.5, 1.0, 1.5, and 2.0 bar) at the same temperature of 8 ºC. The fluxes measured for each pressure ranged from 22, 24, 27 and 30 kg h-1m-2 at 0.5, 1.0, 1.5 and 2.0 bar, respectively. Samples of the feed and permeate were analyzed for pH, color, turbidity, sugar, bitterness, and proteins. The fouling mechanisms observed were cake filtration, partial pore blocking, and complete pore blocking.
Documentos Relacionados
- Oil Removal from Produced Water by Ultrafiltration using Polysulfone Membrane
- Mechanism of Hop-Derived Terpenes Oxidation in Beer
- Detection of Escherichia coli in Foods: Indole Staining Methods for Cellulosic and Polysulfone Membrane Filters
- Evaluation of membrane microfiltration fouling in landfill leachate treatment
- Effect of beer drinking on risk of myocardial infarction: population based case-control study