Análise comparativa da força no limite de escoamento entre um implante de peça única e os de junção hexagonal externa de diâmetros regular e estreito / Análise comparativa da força no limite de escoamento entre um implante de peça única e os de junção hexagonal externa de diâmetros regular e estreito
AUTOR(ES)
Arnaldo Reis Mundim
DATA DE PUBLICAÇÃO
2008
RESUMO
Osseointegrated implants have now been proved to be feasible. However, several factors still remain to be explained, particularly because of the large number of manufacturers and models. Although incidence is low, implant fractures are a clinical reality, and therefore researches are conducted in an endeavor to reduce their number. Objective: To test the hypothesis that the reduction in implant diameter reduces the maximum force required to attain the implant yield limit even when it is made in one piece. Materials and Methods: To test this hypothesis, three implant configurations (SIN) (n=10): HER, external hexagonal junction and regular diameter (3.75mm); HEE, external hexagonal junction and narrow diameter (3.25mm) and UNI, narrow one-piece (2.35mm) were tested. The maximum force at yield limit (N) for the implants was evaluated by means of the flexion test, with force applied perpendicular to the long axis of the implant, at the speed of 0.5 mm/min, in a mechanical test machine. The data were assed by means of the analysis of variance (ANOVA) and Tukey B tests for parametric groups (P<0.05). Results: Statistically significant differences were found between UNI and HER and HEE, and there were no statistically significant differences between the latter two. Conclusions: The UNI group presented statistically lower maximum resistance at the yield limit than the groups HEE and HER.
ASSUNTO(S)
implantes peça única odontologia implantes não submersos implantes estreitos implantes dentários osseointegrados
ACESSO AO ARTIGO
http://www.bdtd.ufu.br//tde_busca/arquivo.php?codArquivo=1909Documentos Relacionados
- Avaliação da força máxima no limite de escoamento do implante cônico interno (3,5mm) comparado aos implantes hexágono externo regular e estreito
- Análise comparativa da precisão de adaptação entre componentes UCLA e implante de um mesmo sistema
- Análise comparativa da tensão limite de escoamento de argamassas por meio da técnica de Pashias e reometria rotacional
- Análise de tensões geradas por implantes de diâmetro largo e junções hexagonal externa, hexagonal interna e cônica interna
- A analise comparativa da junção dentina-esmalte em mamiferos