This paper discusses the performance of an 800m³ full-scale UASB reactor in treating meat-packing plant and slaughterhouse effluents containing high concentrations of oil and grease (O&G) (413-645 mg/L), resulting in a COD/O&G ratio of 26-32%. Those macromolecules were considered responsible for the unbalance of the system resulting in a total washout of the biomass. The removal of O&G from the influent using a physicochemical system (coagulation-flocculation) improved the physical characteristics of the anaerobic sludge, controlling the biomass washout. Reactor performance was significantly improved when the COD/O&G ratio influent was maintained in the 10%. The COD and O&G removal rates obtained after implantation of the physicochemical system were 70-92% and 27-58%, respectively. The specific methanogenic activity (SMA) of the biomass shows towards a tendency stabilisation and adaptation to the substrate influent. Pretreatment of the influent allowed the maximum organic load to be increased (1.46 to 2.43 Kg COD/m³.d) and improved the quality of the effluent.
Documentos Relacionados
- Simulation and calibration of a full-scale sequencing batch reactor for wastewater treatment
- Involvement of Rhodocyclus-Related Organisms in Phosphorus Removal in Full-Scale Wastewater Treatment Plants
- Emergence of Competitive Dominant Ammonia-Oxidizing Bacterial Populations in a Full-Scale Industrial Wastewater Treatment Plant
- Quantification of Nitrosomonas oligotropha-Like Ammonia-Oxidizing Bacteria and Nitrospira spp. from Full-Scale Wastewater Treatment Plants by Competitive PCR
- Numerical forensic model for the diagnosis of a full-scale RC floor